All scenes › Chapter 5 Expansion valve: cold again
1 unit of electricity moves about 4 units of heat
View in 3DCooled to about 7 °C, the refrigerant flows back into the indoor unit and takes in the room’s heat again. It boils in the indoor unit, gets squeezed in the compressor, cools into a liquid in the outdoor unit, and passes through the tiny opening of the expansion valve to get cold again, over and over without stopping. In this example, the air conditioner moves about 4.1 units of heat out of the room for every 1 unit of electricity.
Why?An electric heater makes heat directly from electricity, so 1 unit of electricity gives 1 unit of heat. An air conditioner does not make heat; it only moves it, so it can move several times more heat than the electricity it uses.
Learn moreThe hotter it is outdoors, the hotter the refrigerant must be squeezed, so moving the same heat takes more electricity. Run the refrigerant the other way through the same machine and it becomes a heater (a heat pump) that moves outdoor heat into the room. The ratio of heat moved to electricity used is called the coefficient of performance (COP).
calculated from R-32 property tables (CoolProp) · example: room 27 °C, outdoors 35 °C
View this scene in 3D →Wikipedia: Coefficient of performance · Wikipedia: Vapor-compression refrigeration · CoolProp (Bell et al., 2014)
More in the series
Temperatures, pressures and amounts of heat are calculated from property tables for the refrigerant R-32 (CoolProp). The example is a home air conditioner removing 2.5 kW of heat, with the room at 27 °C and the outdoors at 35 °C. In the 3D view, the refrigerant moves far slower than in real life, and the inside of the compressor and the expansion valve are shown as enlarged, simplified models.